Linear Spindle Actuators PL/PLS 24VDC
Technical Data
| |
Nominal Voltage |
Current Consumption |
Max Lifting force (+ force reserve) |
Lifting speed (28 V DC, 2/3 load) |
Housing Dia |
Duty cycle |
Protection class |
Parallel switching |
Normal service temperature |
| PL 6 |
24 V DC |
Approx. 0.7 A |
600 N |
Approx. 6.5 mm/s |
36mm |
20% |
IP 54 <= 300 stroke IP 65 > 300 stroke |
Yes |
-5° to +70° C |
| PL 10 |
24 V DC |
Approx. 0.8 A <=750mm lift of stroke |
1000 N |
Approx. 3.3 mm/s |
36mm |
20% |
IP 54 <= 300 stroke IP 65 > 300 stroke |
Yes |
-5° to +70° C |
| PLS 10 |
24 V DC |
Approx. 1.2 A |
1000 N |
Approx. 6.7 mm/s |
36mm |
20% |
IP 65 |
Yes |
-5° to +75° C |
| PLS 16 |
24 V DC |
Approx. 1.2 A |
1600 N |
Approx. 3.3 mm/s |
36mm |
20% |
IP 65 |
Yes |
-5° to +75° C |
| PLS 20 |
24 V DC |
Approx. 12.5 A |
2000 N |
Approx. 18 mm/s |
50mm |
20% |
IP 54 |
Yes |
-5° to +75° C |
| PLS 30 |
24 V DC |
Approx. 9.0 A |
3000 N |
Approx. 8 mm/s |
50mm |
20% |
IP 54 |
Yes |
-5° to +75° C |
| PLS 50 |
24 V DC |
Approx. 3.6 A |
5000 N |
Approx. 18 mm/s |
50mm |
20% |
IP 54 |
Yes |
-5° to +75° C |
| |
|
|
|
|
|
|
|
|
|
Bovema manufacture and install Smoke Ventilation Systems, Natural Ventilation Systems, Powered Ventilation Systems and Bespoke Specialist Applications.
All rights reserved
Bovema UK Ltd © 2007