Corrosion resistant aluminium AlMg3 sheet materials;
- AlMgSi 0.5 profiles;
- All fixings are in stainless steel;
- Polycarbonate;
- Nylon bearing.
TMS-D louvres are normally operated from a remote control panel via:
- Pneumatic two pipe systems with actuators, which lock, in the open and closed positions;
- Individual one-shot glass bulb and CO2 emergency actuation, operating at a temperature selected to suit the project requirements, 68, 93, 110 or 140 Deg. C;
- 230 V A/C or 24 V D/C electric actuator operations with fusible link and spring type fire set for emergency operation if required;
- Control panels with protected mains / battery operated systems plus pipe work / wiring as required may also be provided.
Please take notice of the following instructions:
- Only use Stainless steel fixings;
- Drill the holes in the flange with a minimum measure the width of the bolt and a maximum measure of HOH 500 mm;
- Be sure that the voltage is cut off and that there is no pressure on the cylinders. Also the CO2 should not be assembled on the fireset.
- Assembly and maintenance should only be performed in daylight or artificial light.
- Build in length L ≤ 90º and build in width B ≤ 5º.